Exhibitor Products

10 Jul 2026

CETCI ESH Hydrogen Detection System for Critical Battery Safety

Acez Instruments Stand: X57
  • CETCI ESH Hydrogen Detection System for Critical Battery Safety
  • CETCI ESH Hydrogen Detection System for Critical Battery Safety
CETCI ESH Hydrogen Detection System for Critical Battery Safety CETCI ESH Hydrogen Detection System for Critical Battery Safety

The CETCI ESH Hydrogen Detection System is an intelligent gas detection solution designed to provide continuous hydrogen monitoring in UPS battery rooms and lead-acid battery charging areas within mission-critical facilities such as data centres. During battery charging, hydrogen gas may accumulate and create a significant fire and explosion hazard. The ESH system continuously monitors hydrogen concentration and provides early warning before dangerous levels are reached, allowing timely corrective actions.

The system is equipped with configurable audible and visual alarms, relay outputs for automatic exhaust fan interlock, and Building Management System (BMS) integration for centralized monitoring and remote alarm notification. By maintaining a safe battery room environment, the ESH Hydrogen Detection System helps protect personnel, ensures compliance with industry safety standards, minimises downtime, and supports reliable, uninterrupted data centre operations.


Key Features

  • Continuous hydrogen gas monitoring (H₂)
  • Early warning through configurable audible and visual alarms
  • Automatic exhaust fan activation via relay interlock
  • BMS integration (Modbus/BACnet* depending on model)
  • Real-time gas concentration display
  • Adjustable alarm setpoints
  • Easy wall-mounted installation
  • Low maintenance and long-life electrochemical sensor
  • Ideal for UPS rooms, battery rooms, telecom facilities and data centres

Typical Technical Specifications

Parameter Specification
Gas Detected Hydrogen (H₂)
Sensor Technology Electrochemical Hydrogen Sensor
Measuring Range 0–1,000 ppm H₂ (other ranges available depending on model)
Display Digital LCD Display
Alarm Levels User configurable (Low & High Alarm)
Alarm Indicators Audible Buzzer & High-intensity LED
Relay Outputs Alarm Relay + Fan Control Relay
Fan Interlock Automatic exhaust fan activation
Communication Modbus RTU RS-485 / BMS Integration*
Power Supply 24 VDC (Typical)
Response Time <30 seconds (Typical)
Operating Temperature -20°C to +50°C
Protection Rating IP54 (Typical)
Mounting Wall Mount
Application UPS Rooms, Battery Rooms, Data Centres, Telecom Facilities
Loading

2026 Partners

Official Airline Partner


 

Official Event Partner


 

Official Press Release Distribution Partner


 

Official Accreditation Partner


 

Attraction Partner


 

Association Partner


 

Event Partner


 

Event Partner


 

Event Partner


 

Event Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Media Partner


 

Mark Your Calendars