Ⅰ. Product Overview
FULLDE Load Bank is a testing device specifically designed to simulate real-world operating load conditions for power equipment. By converting electrical energy into thermal or other forms of energy dissipation, it enables controlled testing and validation of generator sets, UPS systems, power supply equipment, and electrical power systems. It helps verify equipment performance under rated power and identifies potential issues, ensuring the stability and safety of power system operations.

 

Ⅱ. Core Functions

● Performance Verification: Simulates real operating conditions to test the performance of generators, UPS systems, and power supplies under varying loads.

● Commissioning & Maintenance: Provides conditions for factory testing and on-site commissioning of new equipment, as well as periodic inspection and maintenance.

● Emergency Support: Validates the load-bearing capacity of backup power systems to ensure reliability during power outages or emergencies.

● Data Logging: Collects real-time parameters such as voltage, current, power factor, and frequency to support subsequent operation and maintenance.

 

Ⅲ. Product Classification

By Cooling Method:

1. Air-Cooled Load Bank: Dissipates heat via fans; simple structure and widely used.

2. Liquid-Cooled Load Bank: Uses coolant to remove heat; suitable for high-power-density and high-power scenarios, commonly used in data centers and AI computing centers.

 

By Control Method:

1. Manual Control Type: Adjusts load stepwise via knobs or switches.

2. Automatic Control Type: Programmable control with remote monitoring and step loading/unloading capabilities.

3. Smart Control Type: Features automated testing, data storage, and analysis, compatible with upper-level computers or cloud platforms.

 

By Application Scenario:

1. Generator Test Load Bank

2. UPS Dedicated Load Bank

3. Data Center Simulation Load Cabinet

4. Marine Power Station and Shore Power System Load Bank

 

Ⅳ. Application Fields

1. Data Centers: Validation of UPS, battery packs, and backup power systems.

2. Power Industry: Factory testing, commissioning, and maintenance of generator sets.

3. Marine & Ports: Testing of shipboard power systems and shore power equipment.

4. New Energy: Inspection of photovoltaic/wind power inverters and energy storage systems.

5. Industrial Manufacturing: Load testing of motors, transformers, and power distribution equipment.

 

Ⅴ. Product Advantages

1. Robust Safety: Multiple protection designs, including over-temperature, over-current, short-circuit, and emergency stop protections.

2. Stable Performance: High-quality resistive components ensure long-term operational reliability without performance degradation.

3. Smart Control: Compatible with upper-level computer software for remote monitoring and automated testing.

4. Modular Design: Customizable configurations for easy transportation, expansion, and maintenance.

5. Energy Efficiency & Eco-Friendliness: Some models support waste heat recovery to improve energy utilization.

 

 

Guangdong Fullde Business Scope


 

As a leading manufacturer of power equipment for intelligent computing centers, Fullde primarily engages in the development and sales of:
dummy loads, UPS test load banks (air-cooled rack-mounted load banks, liquid-cooled rack-mounted load banks), immersion liquid-cooled dummy loads, cold plate liquid-cooled dummy loads, DC load banks, diesel generator set test dummy loads, grounding resistance cabinets, high and low voltage AC/DC power distribution cabinets, diesel generator and energy storage integrated cabinets, and all-in-one solar-storage systems.

We also provide:

   ● Load Bank rental services

   ● Turnkey solutions for diesel generator systems

   ● Integrated energy storage system solutions

   ● Prefabricated cabin turnkey services

   ● Containerized solution packages

Furthermore, we offer ODM and OEM services to meet customized requirements.

 

RLC Load Bank Selection Table

NO. Load Type Product Model Resistive power Inductive Capacity Capacitive capacity Minimum step Dimensions (mm) Weight (kg)
1 RLC LB-3kW-3kvar-3kvar-380V-J 3kW 3kvar 3kvar 0.1kW 750*800*1350 55
2 RLC LB-10kW-10kvar-10kvar-230V-J 10kW 10kvar 10kvar 0.1kW 700*800*1600 180
3 RLC LB-30kW-30kvar-30kvar-400V-J 30kW 30kvar 30kvar 0.1kW 800*1000*1600 450
4 RLC LB-50kW-50kvar-50kvar-400V-J 50kW 50kvar 50kvar 0.1kW 750*1000*1600 600
5 RLC LB-100kW-75kvar-75kvar-400V-J 100kW 75kvar 75kvar 1kW 2000*1600*2200 800
6 RLC LB-500kW-500kvar-500kvar-480V-J 500kW 500kvar 500kvar 10kW 4000*2438*2591 6000
7 RLC LB-1000kW-1000kvar-1000kvar-800V-J 1000kW 1000kvar 1000kvar 50kW 6058*2438*2591 8000

 